Chen Jingtao, Duan Fajie, Jiang Jiajia, et al. The establishment and analysis of noise model for pulse modulation dimming method and square-wave modulation dimming method[J]. Opto-Electronic Engineering, 2019, 46(2): 180338. doi: 10.12086/oee.2019.180338
Citation: Chen Jingtao, Duan Fajie, Jiang Jiajia, et al. The establishment and analysis of noise model for pulse modulation dimming method and square-wave modulation dimming method[J]. Opto-Electronic Engineering, 2019, 46(2): 180338. doi: 10.12086/oee.2019.180338

The establishment and analysis of noise model for pulse modulation dimming method and square-wave modulation dimming method

    Fund Project: Supported by the National Key Research and Development Program (2017YFF0204800), National High-tech R & D Program of China (863 Program) (2013AA102402), National Natural Science Foundation of China (61501319), Tianjin Natural Science Foundation (17JCQNJC01100), Photoelectric Information and Instruments Beijing Engineering Research Center Open Project (GD2015007), Regional Demonstration Project for Innovative Development of Marine economy(cxsf2014-2), the Doctoral Program Fund of the Ministry of Education (20130032110054), and Microlight Electromechanical System Technology Ministry of Education Key Laboratory Open Fund (MOMST2015-7)
More Information
  • When measuring the oil concentration lower than 10 mg/L in reinjection water based on ultraviolet fluorescence method, high thermal power of the light source will reduce the accuracy of measurement results. To reduce the thermal power of light source, pulse modulation dimming method (duty ratio less than 50%) was proposed to replace square-wave modulation dimming method (duty ratio equal to 50%). Two noise analysis models for pulse modulation and square-wave modulation dimming method were built. Signal-to-noise ratio (SNR) of measurement results for two methods were compared. The relationship between SNR and light source power was derived. The optimum choices of current amplitude and duty ratio for pulse modulation dimming method were proposed under the condition of the same signal-to-noise ratio. Results show that the light source power for pulse modulation dimming method is less than 21% of that for square-wave modulation dimming method under the condition of the same signal-to-noise ratio. Finally, signal demodulation models of two dimming methods were simulated by MATLAB software. The simulated relationship of SNR for two methods is consistent with the theoretical analysis results.
  • 加载中
  • [1] 朱丽娜.油田注水水质劣化因素与处理技术研究[D].大庆: 东北石油大学, 2013.

    Google Scholar

    Zhu L N. Research on the causes of injection water quality deterioration and treatment technology[D]. Daqing: Northeast Petroleum University, 2013.http://cdmd.cnki.com.cn/Article/CDMD-10220-1013290888.htm

    Google Scholar

    [2] 赵友全, 于海波, 何峰.水中油浓度在线检测方法的研究[J].光谱学与光谱分析, 2013, 33(11): 2949-2952. doi: 10.3964/j.issn.1000-0593(2013)11-2949-04

    CrossRef Google Scholar

    Zhao Y Q, Yu H B, He F. Research on the online detection of oil concentration in water[J]. Spectroscopy and Spectral Analysis, 2013, 33(11): 2949-2952. doi: 10.3964/j.issn.1000-0593(2013)11-2949-04

    CrossRef Google Scholar

    [3] Wang L R, Yang J H. Measurement of micro oil in water by using ultraviolet fluorescence spectrum technology[C]//Proceedings of the 8th International Conference on Electronic Measurement and Instruments, 2007: 3-556-3-559.

    Google Scholar

    [4] 蔡小虎, 蔡述伟, 程青, 等.红外分光光度法测定地下水中的石油类物质[J].化学分析计量, 2014, 23(4): 14-16. doi: 10.3969/j.issn.1008-6145.2014.04.004

    CrossRef Google Scholar

    Cai X H, Cai S W, Cheng Q, et al. Determination of petroleum substance in groundwater by infrared spectrophotometry[J]. Chemical Analysis and Meterage, 2014, 23(4): 14-16. doi: 10.3969/j.issn.1008-6145.2014.04.004

    CrossRef Google Scholar

    [5] 钱贵军, 王学磊, 张小芹.散射透射比值法油分浓度传感器的研究和设计[J].自动化仪表, 2017, 38(2): 86-88, 92.

    Google Scholar

    Qian G J, Wang X L, Zhang X Q. Research and design of the oil content concentration sensor based on scattering-transmission ratio method[J]. Process Automation Instrumentation, 2017, 38(2): 86-88, 92.

    Google Scholar

    [6] El Hussein A, Marzouk A. Characterization of petroleum crude oils using laser induced fluorescence[J]. Journal of Petroleum & Environmental Engineering, 2015, 6(5): 1-6.

    Google Scholar

    [7] Sharikova A V, Killinger D K. LIF detection of trace species in water using different UV laser wavelengths[J]. International Journal of High Speed Electronics and Systems, 2007, 17(4): 689-695. doi: 10.1142/S0129156407004898

    CrossRef Google Scholar

    [8] 李丹.紫外荧光法水中油检测技术和实验的研究[D].天津: 天津大学, 2009.

    Google Scholar

    Li D. Study on the measuring technology and experiments of oil in water using UV fluorometry[D]. Tianjin: Tianjin University, 2009.http://cdmd.cnki.com.cn/Article/CDMD-10220-1013290888.htm

    Google Scholar

    [9] Sharikova A V, Killinger D K. Laser- and UV-LED-Induced fluorescence detection of drinking water and water-dissolved organics[C]//Digital Holography and Three-Dimensional Imaging, 2008.

    Google Scholar

    [10] 赵广立, 冯巍巍, 付龙文.等.基于紫外荧光法检测水中油含量的浸入式传感装置的研究[J].海洋通报, 2014, 33(1): 77-83.

    Google Scholar

    Zhao G L, Feng W W, Fu W L, et al. Research on a submersible oil-in-water detection probe based on ultraviolet fluorescence analysis technique[J]. Marine Science Bulletin, 2014, 33(1): 77-83.

    Google Scholar

    [11] 许飞.散射和荧光法油田注水在线检测系统研究[D].天津: 天津大学, 2016.

    Google Scholar

    Xu F. Study on the oilfield injection water online detection system using scattering and fluorescence[D]. Tianjin: Tianjin University, 2016.http://cdmd.cnki.com.cn/Article/CDMD-10056-1017060632.htm

    Google Scholar

    [12] 斯容, 卢瑜林, 邓学峰, 等.渭北油田回注水中悬浮物和油含量指标及控制技术[J].油气藏评价与开发, 2016, 6(2): 51-53, 59. doi: 10.3969/j.issn.2095-1426.2016.02.012

    CrossRef Google Scholar

    Si R, Lu Y L, Deng X F, et al. Content indicators and control technology of suspended solid and oil of reinjection water in Weibei oilfield[J]. Reservoir Evaluation and Development, 2016, 6(2): 51-53, 59. doi: 10.3969/j.issn.2095-1426.2016.02.012

    CrossRef Google Scholar

    [13] 吴玉香, 尚俊, 王孝洪, 等.一种基于脉冲宽度调制和脉冲幅度调制的发光二极管驱动器[J].光学学报, 2015, 35(9): 0922003.

    Google Scholar

    Wu Y X, Shang J, Wang X H, et al. A light emitting diode driver based on pulse width modulation and pulse amplitude modulation diming[J]. Acta Optica Sinica, 2015, 35(9): 0922003.

    Google Scholar

    [14] 梅毅, 陈郁阳, 袁川, 等. LED温度特性的测试[J].照明工程学报, 2007, 18(1): 17-20. doi: 10.3969/j.issn.1004-440X.2007.01.005

    CrossRef Google Scholar

    Mei Y, Chen Y Y, Yuan C, et al. Measurement of LEDs' temperature characteristics[J]. China Illuminating Engineering Journal, 2007, 18(1): 17-20. doi: 10.3969/j.issn.1004-440X.2007.01.005

    CrossRef Google Scholar

    [15] 王健, 黄先, 刘丽, 等.温度和电流对白光LED发光效率的影响[J].发光学报, 2008, 29(2): 358-362.

    Google Scholar

    Wang J, Huang X, Liu L, et al. Effect of temperature and current on LED luminous efficiency[J]. Chinese Journal of Luminescence, 2008, 29(2): 358-362.

    Google Scholar

  • Overview: When using crude oil for producing qualified oil and gas production, we need to separate the water from the crude oil which is called oil sewage. The oil sewage contains a certain amount of oil and other impurities. The oil sewage is usually reinjected back under the ground after multiple processes. To avoid the excess oil of reinjection water affecting the quality of underground water source, it is important to ensure that the oil concentration is lower than requirement. Oil concentration measurement methods include infrared spectrophotometry, nephelometry, ultraviolet spectrophotometry and ultraviolet fluorescence. The ultraviolet fluorescence method has the advantages of real-time and high precision. The oil concentration of purified reinjection water is usually lower than 10 mg/L, so the ultraviolet fluorescence method is more suitable in this situation. To accurately measure the concentration of reinjection water based on ultraviolet fluorescence method, high transmission power of light emitting diode (LED) is required, so that the fluorescence of aromatics in oil is sufficient to be detected. In early experiments, the oil concentration is measured by square-wave dimming method (duty ratio equal to 50%). The chip temperature of LED will be higher than requirement because of the high transmission power of LED, thereby, LED luminous efficiency will be drastically reduced, and LED devices will be even damaged. To solve this problem, this paper proposed the pulse modulation dimmer method (duty ratio less than 50%) to reduce the LED average power and increase instantaneous power, which could ensure high signal-to-noise ratio (SNR). Pulse modulation dimming method makes LED produce higher transient light intensity and shortens the amount of conduction time in unit time. Two noise analysis models for pulse modulation and square-wave modulation dimming method were built. The discussion focused on wideband limiting in square-wave dimming method and the influence of noise aliasing in pulse modulation dimmer method. Signal-to-noise ratio of measurement results for two methods were compared under several condition. The relationship among SNR, light source power and duty ratio was derived. The optimum choices of current amplitude and duty ratio for pulse modulation dimming method were proposed under the condition of the same signal-to-noise ratio. Results show that the light source power for pulse modulation dimming method is less than 21% of that for square-wave modulation dimming method under the condition of the same signal-to-noise ratio. Finally, signal demodulation models of two dimming methods were simulated by MATLAB software. The simulated relationship of SNR for two methods is consistent with the theoretical analysis results.

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(8)

Tables(3)

Article Metrics

Article views(7303) PDF downloads(2582) Cited by(0)

Access History
Article Contents

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint